DLHPVHBR/LHPVHBR Sterilizing-Grade Liquid Filter
Cobetter's DLHPVHBR/LHPVHBR series filter cartridge is made of hydrophilic and positively-charged PVDF membrane. PVDF's unique very low protein adsorption performance makes it particularly suitable for filtration of culture fluids, biological reagents, sterile vaccines, etc. At the same time, DLHPVHBR/LHPVHBR has low leachables, wide chemical compatibility, and very excellent temperature resistance.
Recommended Applications:
Request a Quote
Description
Features
- Very low protein adsorption properties
- Good corrosion, oxidation and heat resistance
- Low leachables
- Good chemical compatibility
- 100% integrity testing to ensure sterilization performance
Applications
- Blood product filtration
- Antibiotic solution sterile filtration
- Biological reagent filtration
- Vaccine filtration
Quality
- 100% Integrity testing in manufacturing
- Each filter is fully traceable with unique serial number
- Manufactured in a facility which adheres to ISO 9001:2015 Practices
Flow Rate Characteristics

Specifications
Materials of Construction
Membrane | Hydrophilic polyvinylidene fluoride (PVDF) |
Support | Polypropylene (PP) |
Core/Cage/End Caps | Polypropylene (PP) |
End Cap Inserts | Polybutylene terephthalate (PBT) |
Seal Material | Silicone / EPDM / Viton FEP/ PFA encapsulated O-rings |
Operating Conditions
Max. Operating Temperature |
80°C |
Max.Operating Pressure |
0.69 MPa@25°C 0.40 MPa@60°C 0.24 MPa@80°C |
Max. Differential Pressure (Forward) |
0.69 MPa@25°C 0.40 MPa@60°C 0.24 MPa@80°C |
Max. Differential Pressure (Reverse) |
0.30 MPa@25°C 0.10 MPa@80°C |
Filtration Area
Outer Diameter | Membrane Pore Size | Area/10" | |
DLHPVHBR | 69 mm | 0.1+0.1 μm | 0.58 m² |
69 mm | 0.22+0.1 μm | 0.58 m² | |
69 mm | 0.22+0.22 μm | 0.58 m² | |
69 mm | 0.45+0.22 μm | 0.58 m² | |
69 mm | 0.65+0.22 μm | 0.58 m² | |
LHPVHBR | 69 mm | 0.22 μm | 0.58 m² |
69 mm | 0.45 μm | 0.58 m² |
Integrity Test Standards @10inch,20°C (DLHPVHBR)
Membrane Pore Size | Bubble Point | Air Diffusion |
0.1+0.1 μm | ≥ 0.48 MPa (water), Air Testing | ≤ 15 ml/min @ 0.386 MPa (water) |
0.22+0.1 μm | ≥ 0.48 MPa (water), Air Testing | ≤ 20 ml/min @ 0.386 MPa (water) |
0.22+0.22 μm | ≥ 0.32 MPa (water), Air Testing | ≤ 18 ml/min @ 0.28 MPa (water) |
0.45+0.22 μm | ≥ 0.32 MPa (water), Air Testing | ≤ 20 ml/min @ 0.28 MPa (water) |
0.65+0.22 μm | ≥ 0.32 MPa (water), Air Testing | ≤ 20 ml/min @ 0.28 MPa (water) |
Integrity Test Standards @10inch,20°C (LHPVHBR)
Membrane Pore Size | Bubble Point | Air Diffusion |
0.1 μm | / | ≤ 30 ml/min @ 0.386 MPa (water) |
0.22 μm | ≥ 0.32 MPa (water), Air Testing | ≤ 20 ml/min @ 0.28 MPa (water) |
0.45 μm | ≥ 0.12 MPa (water), Air Testing | ≤ 10 ml/min @ 0.10 MPa (water) |
Bacterial Retention
Model | Content |
DLHPVHBR 0.22+0.1μm | Bacterial quantitative retention of 10⁷ cfu/cm² Brevundimonas diminuta (ATCC 19146) accordingto ASTM F838 methodology. |
DLHPVHBR 0.22+0.22μm | |
DLHPVHBR 0.22+0.1μm | |
DLHPVHBR 0.45+0.22μm | |
DLHPVHBR 0.65+0.22μm | |
LHPVHBR 0.1μm | Bacterial quantitative retention of 10⁷ cfu/cm² Brevundimonas diminuta (ATCC 19146) accordingto ASTM F838 methodology. |
LHPVHBR 0.22μm |
Sterilization
In-line steam sterilization | DLHPVHBR Up to 150 cycles (135°C for 30 min, differential pressure <30kPa in the forward direction with 100 cycles and <10kPa in the reverse direction with 50 cycles) LHPVHBR Up to 70 cycles (135°C for 30 min and differential pressure <30kPa) |
Autoclave | Up to 400 cycles (130 °C for 30 min per cycle) |
Regulatory Compliance
- Autoclaved filter effluent meets the USP<788> requirement of particulate matter in large volume injection.
- Component materials meet the criteria for a "Non-fiber-releasing filter" as defined in 21 CFR 210.3(b)(6).
- Aqueous extraction from a cartridge contains less than 0.25EU/ml as determined by Limulus Amebocyte Lysate (LAL), meeting requirements of USP<85>.
- Meet the requirement of USP <87> In Vitro Cytotoxicity Test.
- Component materials meet the requirements of the current USP<88> for plastic class VI-121°C.
- All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
- Based on the current information from our suppliers, all component materials used in the manufacture of this product are animal-free.
End Cap

Ordering Information
DLHPVHBR (Double-layer)
Outer Diameter | Type | Membrane Pore Size | End Cap | Nominal Length | Seal Material | Industry |
69mm | DLHPVHBR | 1010 0.1+0.1µm | DOE Double Open End | 05 5 inch | S Silicone | P |
2210 0.22+0.1µm | HTF 222/Fin | 10 10 inch | E EPDM | |||
2222 0.22+0.22µm | HSF 226/Fin | 20 20 inch | V Viton | |||
4522 0.45+0.22µm | HTCG 222/Flat | 30 30 inch | P FEP/PFA encapsulated O-rings | |||
6522 0.65+0.22µm | HSCG 226/Flat | 40 40 inch |
LHPVHBR (Single-layer)
Outer Diameter | Type | Membrane Pore Size | End Cap | Nominal Length | Seal Material | Industry |
69mm | LHPVHBR | 0022 0.22µm | DOE Double Open End | 05 5 inch | S Silicone | P |
0045 0.45μm | HTF 222/Fin | 10 10 inch | E EPDM | |||
HSF 226/Fin | 20 20 inch | V Viton | ||||
HTCG 222/Flat | 30 30 inch | P FEP/PFA encapsulated O-rings | ||||
HSCG 226/Flat | 40 40 inch |